Transformers

Control transformers VDE 0570 (EN 61558 / IEC 61558)

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Control transformer, single phaseSTS (in Stock)0,05 kVA – 2,5 kVAPrimary: 230V/400V +-15V

Sekundary: 24V or 230V

Control transformer, single phaseST-V (in Stock)0,1 kVA – 1,6 kVAPrimary: 208V-230V-380V-400V-415V-440V-460V-480V-500V-525V-550V

Sekundary: 24V or 2x115V (230V)

Control transformer, single phaseST0,05 kVA – 2,5 kVAPrimary: alternatively a voltage between 100V – 750V

Sekundary: alternatively a voltage between 5V – 750V

Control transformer, single phaseSD2,0 kVA – 10,0 kVAPrimary: alternatively a voltage between 100V – 750V

Sekundary: alternatively a voltage between 5V – 750V

Control transformer, single phaseSL2,0 kVA – 10,0 kVAPrimary: alternatively a voltage between 100V – 750V

Sekundary: alternatively a voltage between 5V – 750V

Tensions and performance differing on request.
The types ST, SD and SL can also be manufactured in (UL506) upon request.  ul-zulassung-ul506-logo-s-100x46

Click here to go directly to the order form

Isolating transformers VDE 0570 (EN 61558 / IEC 61558)

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Isolating transformer, single phaseNT0,05 kVA – 2,5 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, single phaseNS2,0 kVA – 10,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, single phaseNL2,0 kVA – 10,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, single phaseME10,0 kVA – 100,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, single phaseMEG10,0 kVA – 100,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Tensions and performance differing on request.

The types ME and MEG can also be manufactured in (UL506) upon request.ul-zulassung-ul506-logo-s-100x46

Isolating transformers for the supply of medical rooms VDE 0570-2-15 / VDE 0100-70

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Isolating transformer, single phase

Isolating transformer, single phase

SM / LM3,15 kVA – 8,0 kVAPrimary: 230V

Sekundary: 230V

Isolating transformer, three phase

Isolating transformer, three phase

DSM / DLM3,15 kVA – 10,0 kVAPrimary: 3x400V

Sekundary: 3x230V

Click here to go directly to the order form

Auto transformer VDE 0570-2-13 (EN 61558 / IEC 61558)

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Auto transformer, single phaseVT0,05 kVA – 2,5 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Auto transformer, single phaseVS2,0 kVA – 10,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Auto transformer, single phaseVL2,0 kVA – 10,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Tensions and performance differing on request.

The types VT, VS and VL can also be manufactured in (UL506) upon request.ul-zulassung-ul506-logo-s-100x46

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Auto transformer, three phaseDSsp0,1 kVA – 15,0 kVAPrimary:alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Auto transformer, three phaseDLsp0,3 kVA – 12,5 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Auto transformer, three phaseMDsp12,5 kVA – 160 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Auto transformer, three phaseMDspG12,5 kVA – 160 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Tensions and performance differing on request.

The types DSsp, DLsp, MDsp can also be manufactured in (UL506) upon request.ul-zulassung-ul506-logo-s-100x46

Click here to go directly to the order form

Transformer starters

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Transformer starter, three phaseDAT0,1 kVA – 200 kVAPrimary: customer specifications

Sekundary: customer specifications

Can also be manufactured in (UL506) upon request.  ul-zulassung-ul506-logo-s-100x46

Click here to go directly to the order form

Isolating transforer, three-phase

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Isolating transformer, three phaseDS0,1 kVA – 15,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, three phaseDL0,3 kVA – 15,0 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, three phaseMD12,5 kVA – 630 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary: alternatively a voltage between 5V – 750V

Isolating transformer, three phaseMDG IP2312,5 kVA – 630 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary:alternatively a voltage between 5V – 750V

Isolating transformer, three phaseMDG IP5412,5 kVA – 630 kVAPrimary: alternatively a voltage between 100V bis 750V

Sekundary:alternatively a voltage between 5V – 750V

Tensions and performance differing on request.

The types DS, DL, MD can also be manufactured in (UL506) upon request.ul-zulassung-ul506-logo-s-100x46

Click here to go directly to the order form

Safety isolatingtransformer VDE 0570 (EN 61558 / IEC 61558)

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Safety isolating transformer, single phaseKT0,05 kVA – 1,6 kVAPrimary: alternatively a voltage between 100V bis 500V

Sekundary: alternatively a voltage between 2V – 42V

Safety isolating transformer, single phase, grouted; IP 30PSS (for Switchboard installation, TS35)0,01 kVA – 0,1 kVAPrimary: 230V

Sekundary: 24V

Safety isolating transformer, single phase, grouted; IP 65EVGT (Stationary)0,05 kVA – 1,0 kVAPrimary: 230V

Sekundary: 230V

Safety isolating transformer, single phase, grouted; IP 65EVG (Stationary)0,05 kVA – 1,0 kVAPrimary: 230V

Sekundary: 42V

Safety isolating transformer, single phase, grouted; IP 65EVGE (Stationary)0,05 kVA – 1,0 kVAPrimary: 230V

Sekundary: 24V

Safety isolating transformer, single phase, grouted; IP 44ETH (Change of location)0,1 kVA – 3,5 kVAPrimary: 230V

Sekundary: 24V oder 42V

Safety isolating transformer, single phase, grouted; IP 44ETC (Change of location)0,1 kVA – 3,5 kVAPrimary: 230V

Sekundary: 24V oder 42V

Safety isolating transformer, single phase, grouted; IP 44ETR (Change of location)0,1 kVA – 3,5 kVAPrimary: 230V

Sekundary: 230V

Safety isolating transformer, single phase, grouted; IP 54LTW (12V Halogen lamps)0,05 kVA – 0,5 kVAPrimary: 230V

Sekundary: 12V

Safety isolating transformer, single phase, grouted; IP 65EVGS (12V Swimming pool lighting)0,05 kVA – 0,9 kVAPrimary: 230V

Sekundary: 12V

Safety isolating transformer, single phase, grouted; IP 65EVGM (12V Swimming pool lighting)0,05 kVA – 0,9 kVAPrimary: 230V

Sekundary: 12V, 13V, 14V

Click here to go directly to the order form

Toroidal variable transformer

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Toroidal variable transformer, single phaseM1,0A – 32,0APrimary: 230V

Sekundary: 0 – 230V

Toroidal variable transformer, single phaseMG1,0A – 32,0APrimary: 230V

Sekundary: 0 – 230V

PRODUCTTYPE DESIGNATIONPERFORMANCE AREA IN KVAPRIMARY / SEKUNDARY
Ringstelltransformator, dreiphasigDMO1,0A – 32,0APrimary: 3x400V

Sekundary: 3×0 – 400V

Ringstelltransformator, dreiphasigDMG1,0A – 32,0APrimary: 3x400V

Sekundary: 3×0 – 400V

Click here to go directly to the order form